Filling most of the UI elements with data

This commit is contained in:
jpk 2020-01-24 16:45:24 +01:00
parent cc58b11aef
commit e26291be05
3 changed files with 195 additions and 41 deletions

View File

@ -48,13 +48,14 @@ class Ui_MainWindow(object):
self.horizontalLayout_2 = QHBoxLayout(self.frame)
self.horizontalLayout_2.setObjectName(u"horizontalLayout_2")
self.comboDevices = QComboBox(self.frame)
self.comboDevices.setEnabled(False)
self.comboDevices.setObjectName(u"comboDevices")
self.horizontalLayout_2.addWidget(self.comboDevices)
self.buttonConnection = QPushButton(self.frame)
self.buttonConnection.setObjectName(u"buttonConnection")
self.buttonConnection.setFlat(False)
self.buttonConnection.setEnabled(False)
self.horizontalLayout_2.addWidget(self.buttonConnection)

View File

@ -128,16 +128,19 @@ def is_connected():
return False
def get_meter_stats():
def get_meter_stats(timeout=50):
global rfcomm
rfcomm.send(UM24C_GET_STATUS)
sleep(0.25)
sleep(timeout)
data = rfcomm.recv(0x8f)
assert len(data) == 130
assert data[0:2] == PACKET_MAGIC[0] and data[-2:] == PACKET_MAGIC[1]
values = list(unpack(DATA_FORMAT, data))
for i, value in enumerate(values):
if type(value) is bytes:
values[i] = int.from_bytes(value.strip(b'\x00'), 'big',
signed=False)
return UMeterStatus(*values)
# assert len(data) == 130
# assert data[0:2] == PACKET_MAGIC[0] and data[-2:] == PACKET_MAGIC[1]
try:
values = list(unpack(DATA_FORMAT, data))
for i, value in enumerate(values):
if type(value) is bytes:
values[i] = int.from_bytes(value.strip(b'\x00'), 'big',
signed=False)
return UMeterStatus(*values)
except:
return None

View File

@ -1,9 +1,10 @@
#!/usr/bin/env python
import sys
import traceback
import random
from PySide2.QtCore import (
Qt, QTimer
Qt, QTimer, QObject, Signal, Slot, QRunnable, QThreadPool
)
from PySide2.QtWidgets import (
QApplication, QMainWindow
@ -17,6 +18,89 @@ from UM24CUI import Ui_MainWindow
from meter import um24c
class WorkerSignals(QObject):
"""
Defines the signals available from a running worker thread.
Supported signals are:
finished
No data
error
`tuple` (exctype, value, traceback.format_exc() )
result
`object` data returned from processing, anything
progress
`int` indicating % progress
"""
finished = Signal()
error = Signal(tuple)
result = Signal(object)
progress = Signal(int)
class MeterSignals(WorkerSignals):
progress = Signal(object)
class UM24LabUIWorker(QRunnable):
def __init__(self, fn, *args, **kwargs):
super(UM24LabUIWorker, self).__init__()
self.fn = fn
self.args = args
self.kwargs = kwargs
self.signals = WorkerSignals()
self.kwargs['progress_callback'] = self.signals.progress
@Slot()
def run(self):
try:
result = self.fn(*self.args, **self.kwargs)
except:
traceback.print_exc()
exctype, value = sys.exc_info()[:2]
self.signals.error.emit((exctype, value, traceback.format_exc()))
else:
self.signals.result.emit(result)
finally:
self.signals.finished.emit()
class UM24LabWorker(UM24LabUIWorker):
def __init__(self, fn, *args, **kwargs):
super(UM24LabUIWorker, self).__init__()
self.fn = fn
self.args = args
self.kwargs = kwargs
self.signals = MeterSignals()
self.kwargs['progress_callback'] = self.signals.progress
@Slot()
def run(self):
while um24c.is_connected():
try:
result = self.fn(*self.args, **self.kwargs)
except:
traceback.print_exc()
exctype, value = sys.exc_info()[:2]
self.signals.error.emit((exctype, value, traceback.format_exc()))
else:
self.signals.result.emit(result)
finally:
self.signals.finished.emit()
class UM24Lab(QMainWindow):
def __init__(self):
@ -24,19 +108,37 @@ class UM24Lab(QMainWindow):
self.ui = Ui_MainWindow()
self.ui.setupUi(self)
self.threadpool = QThreadPool()
self.meter_stats = None
self.ui.labelTimeRecorded.setText('00:00:00')
self.ui.sliderBrightness.setValue(0)
self.ui.sliderScreenOff.setValue(0)
self.ui.lcdVoltage.display(0.00)
self.ui.lcdCurrent.display(0.00)
self.ui.lcdImpedance.display(0.00)
self.ui.lcdPower.display(0.00)
self.ui.lcdTempC.display(0)
self.ui.lcdTempF.display(0)
self.ui.progressTempC.setValue(0)
self.ui.progressTempF.setValue(0)
self.ui.lcdDataMinus.display(0.00)
self.ui.lcdDataPlus.display(0.00)
self.ui.lcdCapacityRecorded.display(0)
self.ui.lcdEnergyRecorded.display(0)
self.ui.spinStopCurrent.setValue(0.00)
self.ui.buttonGroup.buttons()[0].setChecked(True)
# TODO: Add splash screen, discover in background
self.connected = False
supported_devices = um24c.discover_devices()
for device in supported_devices:
self.ui.comboDevices.addItem(device[0])
self.ui.buttonConnection.clicked.connect(self.connect_device)
self.action_discover_devices()
# --- Plot setup ---
self._setup_plots()
self.timer_step = 0
timer = QTimer(self)
timer.timeout.connect(self.update_graphs)
timer.start(200)
timer.start(50)
def _setup_plots(self):
self.ui.plotVoltage = QtCharts.QChart()
@ -89,40 +191,88 @@ class UM24Lab(QMainWindow):
self.current.addAxis(axis_y, Qt.AlignLeft)
self.current_series.attachAxis(axis_y)
def connect_device(self):
if not self.connected:
def do_discover_devices(self, progress_callback):
return um24c.discover_devices()
def discover_devices_finished(self):
if self.ui.comboDevices.count() > 0:
self.ui.comboDevices.setEnabled(True)
self.ui.buttonConnection.setEnabled(True)
def discover_devices_result(self, devices):
for device in devices:
self.ui.comboDevices.addItem(device[0])
self.ui.buttonConnection.clicked.connect(self.action_connect_device)
def action_discover_devices(self):
worker = UM24LabUIWorker(self.do_discover_devices)
worker.signals.result.connect(self.discover_devices_result)
worker.signals.finished.connect(self.discover_devices_finished)
# worker.signals.progress.connect(...)
self.threadpool.start(worker)
def do_connect_device(self, progress_callback):
if not um24c.is_connected():
um24c.connect(self.ui.comboDevices.currentText())
if um24c.is_connected():
self.ui.buttonConnection.setText('Disconnect')
self.ui.comboDevices.setEnabled(False)
self.connected = True
return True
else:
um24c.disconnect()
if not um24c.is_connected():
self.ui.buttonConnection.setText('Connect')
self.ui.comboDevices.setEnabled(True)
self.connected = False
return False
def connect_device_result(self, status):
self.ui.comboDevices.setEnabled(not status)
if status:
self.ui.buttonConnection.setText('Disconnect')
self.action_update_stats()
else:
self.ui.buttonConnection.setText('Connect')
def action_connect_device(self):
worker = UM24LabUIWorker(self.do_connect_device)
worker.signals.result.connect(self.connect_device_result)
# worker.signals.finished.connect(...)
# worker.signals.progress.connect(...)
self.threadpool.start(worker)
def do_update_stats(self, progress_callback):
while um24c.is_connected:
current = um24c.get_meter_stats()
progress_callback.emit(current)
def update_stats_progress(self, current):
self.meter_stats = current
def action_update_stats(self):
worker = UM24LabWorker(self.do_update_stats)
worker.signals.progress.connect(self.update_stats_progress)
self.threadpool.start(worker)
def update_graphs(self):
if um24c.is_connected():
self.meter_stats = um24c.get_meter_stats()
print(self.meter_stats)
self.ui.lcdVoltage.display(self.meter_stats.Voltage / 100)
self.ui.lcdCurrent.display(self.meter_stats.Current / 100)
self.ui.lcdImpedance.display(self.meter_stats.Load_equivalent_impedance
/ 10)
self.ui.lcdPower.display(self.meter_stats.Power / 100)
self.ui.lcdTempC.display(self.meter_stats.Temperature_Celcius)
self.ui.lcdTempF.display(self.meter_stats.Temperature_Fahrenheit)
# self.ui.progressTempC.setValue(self.meter_stats.Temperature_Celcius)
# self.ui.progressTempF.setValue(self.meter_stats.Temperature_Fahrenheit)
self.ui.lcdDataMinus.display(self.meter_stats.DMinus / 100)
self.ui.lcdDataPlus.display(self.meter_stats.DPlus / 100)
self.ui.lcdCapacityRecorded.display(self.meter_stats.Recorded_Capacity)
self.ui.lcdEnergyRecorded.display(self.meter_stats.Recorded_Energy)
self.ui.spinStopCurrent.setValue(self.meter_stats.Current_Trigger /
100)
if um24c.is_connected() and self.meter_stats:
ui = self.ui
ui.lcdVoltage.display(self.meter_stats.Voltage / 100)
ui.lcdCurrent.display(self.meter_stats.Current / 100)
ui.lcdImpedance.display(self.meter_stats.Load_equivalent_impedance
/ 10)
ui.lcdPower.display(self.meter_stats.Power / 100)
ui.lcdTempC.display(self.meter_stats.Temperature_Celcius)
ui.lcdTempF.display(self.meter_stats.Temperature_Fahrenheit)
ui.progressTempC.setValue(self.meter_stats.Temperature_Celcius)
ui.progressTempF.setValue(self.meter_stats.Temperature_Fahrenheit)
ui.lcdDataMinus.display(self.meter_stats.DMinus / 100)
ui.lcdDataPlus.display(self.meter_stats.DPlus / 100)
ui.lcdCapacityRecorded.display(self.meter_stats.Recorded_Capacity)
ui.lcdEnergyRecorded.display(self.meter_stats.Recorded_Energy)
ui.spinStopCurrent.setValue(self.meter_stats.Current_Trigger / 100)
ui.sliderBrightness.setValue(self.meter_stats.Display_brightness)
ui.sliderScreenOff.setValue(self.meter_stats.Display_timeout)
ui.buttonGroup.buttons()[self.meter_stats.Current_screen].setChecked(True)
# self.voltage_series.append(self.timer_step, random.randint(0, 10))
# self.current_series.append(self.timer_step, random.randint(0, 10))